Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.

2013

Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …

Adultmedicine.medical_specialtyIntraocular pressurePhakic Intraocular Lensesgenetic structuresVisual AcuitySpherical equivalentBiocompatible MaterialsCell CountRefraction OcularSafety indexCorneaYoung AdultLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreImplantable collamer lensEfficacy indexbusiness.industryEndothelium CornealMiddle Agedeye diseasesSensory SystemsPosterior chamber phakic intraocular lensEndothelial cell densityOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery